Foil-Tec - Timber Frame
- Single
- Double
Installation of Foil-Tec VCL Single for Timber frame applications and additional insulation products should be in accordance with the manufacturers fixing instructions, certification and current good building practice.
Foil-Tec VCL is applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the stud. The foil side of the material should face the adjacent air space. All overlaps and perimeters must be taped and sealed using YBS Foil Tape.
If there is no cavity present between the studs, fix horizontal counter battens, minimum 25mm by 38mm, to the timber frame at appropriate centres. Battens must always be placed at the top and bottom of the wall and around the perimeter of doors and windows.
The plasterboard is fixed to the battens in accordance with manufacturers fixing instructions.
Description (Foiltec Single - Breather Foil) | U-Value |
---|---|
95mm Mineral Wool (0.044 W/mK) | 0.28 W/m²K |
115mm Mineral Wool (0.040 W/mK) | 0.25 W/m²K |
140mm Mineral Wool (0.040 W/mK) | 0.22 W/m²K |
120mm PIR (0.022 W/mK) | 0.19 W/m²K |
Description (Foiltec Single - Standard Breather Membrane) | U-Value |
---|---|
140mm Mineral Wool (0.044 W/mK) | 0.27 W/m²K |
140mm Mineral Wool (0.040 W/mK) | 0.25 W/m²K |
125mm PIR (0.022 W/mK) | 0.22 W/m²K |
140mm PIR (0.022 W/mK) | 0.19 W/m²K |
Installation of Foil-Tec VCL Double for Timber frame applications and additional insulation products should be in accordance with the manufacturers fixing instructions, certification and current good building practice.
Foil-Tec VCL is then applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the studs. The foil sides of the material will be facing the cavities formed. All overlaps and perimeters must be taped and sealed using YBS Foil Tape.
Horizontal counter battens, minimum 25mm by 38mm are fixed to the wall at 400mm centres. Battens must always be placed at the top and bottom of the wall and around the perimeter of doors and windows.
The plasterboard is fixed to the battens in accordance with manufacturers fixing instructions.
Description (Foil-Tec Double - Breather Foil) | U-Value |
---|---|
60mm Mineral Wool (0.044 W/mK) | 0.28 W/m²K |
80mm Mineral Wool (0.044 W/mK) | 0.25 W/m²K |
125mm Mineral Wool (0.044 W/mK) | 0.22 W/m²K |
90mm PIR (0.022 W/mK) | 0.19 W/m²K |
Description (Foil-Tec Double - Standard Breather Membrane) | U-Value |
---|---|
95mm Mineral Wool (0.044 W/mK) | 0.28 W/m²K |
115mm Mineral Wool (0.040 W/mK) | 0.25 W/m²K |
90mm PIR (0.022 W/mK) | 0.22 W/m²K |
120mm PIR (0.022 W/mK) | 0.19 W/m²K |